Sayyed Fire Integration
Fire extinguishers

Trolley-mounted fire extinguishers

Higher-capacity wheeled units for yards, plant areas, fuel installations and warehouses — more agent, longer discharge and a longer hose reach.

Photo — trolley-mounted extinguisher at a plant yard parking position
Practice
IS 10658 · IS 2190
Typical use
Yards, plant, fuel installations
Service
Annual · refill · hydro-test
What it is

When a nine kilo unit is not going to be enough

A hand extinguisher gives you a few kilos of agent and around fifteen seconds of discharge from two or three metres away. On a transformer yard, a fuel loading point, a bulk store or a plant floor, that is not a proportionate response to the risk — the fire will be larger than the unit before anyone reaches it, and the operator needs to stand further back than a hand unit allows.

A trolley unit answers both problems: substantially more agent, a discharge measured in tens of seconds, and a hose that lets the operator work from a standoff. It is still a first-aid appliance operated by one person, which is exactly its role in the gap between the portable inventory and the fixed system or the brigade.

What it needs from the design is access. A wheeled unit is useless if it cannot be got to the fire — the route has to be hard-standing, kerbs and steps have to be considered, and the parking position has to be upwind and clear. We survey the routes as part of specifying these, supply and site the units, and cover the annual check, refilling and pressure-test cycle under contract.

Equipment

Types and capacities

Agent chosen against the risk exactly as for a hand unit; the capacity and the hose length are what make it a trolley.

ABC powder — 25 kg and 50 kgMixed-risk plant areas, warehouses and loading bays.
BC powder — 25 kg and 75 kgFuel installations, LPG manifolds and dispensing points.
CO₂ — 22.5 kg and 45 kgSubstations, switch rooms and transformer yards, where residue cannot be left on the plant.
Foam — 50 litre and 100 litreBunded areas, tank farms and spill risks needing sustained application.
Water — 45 litre and aboveTimber yards, stockpiles and bulk Class A storage.
Hose, nozzle and reelThe reach that lets one person work at a standoff from the fire.
Wheels, frame and parking positionPneumatic wheels for a real yard surface, and a marked position that is upwind and unobstructed.
Refilling and hydrostatic testingAnnual check, refill after any use and pressure test on the required cycle, recorded per unit.

Tell us about the project

Send the drawings or the BOQ and we will price it line by line. Most enquiries start with a site visit, because the site decides the system — not the catalogue.